Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
Each phase of a delta-connected load comprises a resistance of 30 and an 80 μF capacitor in series. The load is connected to a 400 V, 50 Hz, 3-phase supply. Calculate (a) the phase current, (b) the line current, (c) the total power dissipated and (d) the kVA rating of the load.
Give a different equation, in terms of the input and output, to describe the system. Is the system stable?
A 1.2 MW wind turbine has a rotor diameter of 64 m. the turbine operates in an area with an average wind velocity of 7.5 m/s and the air density of 1.18 kg/m^3. the turbine power coefficient including the unit efficiency is 42.8 percent.
An 8mm thick brass [E=83 GPa; v = 0.33] plate is subjected to biaxial stress with sigma x = 180 MPa and sigma y = 65 MPa. The plate dimensions are b = 350 mm and h = 175 mm.
How much charge is inside this 34.0-cm diameter spherical surface
An open-circuited 50 Ω microstrip transmission line is used ina microwave amplifier circuit to provide a capacitance of 3.2 pF at2.3 GHz. (a) Find the appropriate electrical length of the line
a. What are the effective bandwidths of the two devices?
Implement the following Boolean function with an 8-to-1-line multiplexer and a single inverter with variable D as its input: F(A,B,C,D)= Em(2,4,6,9,10,11,15)
A zero mean gaussian random vector X=(X1, X2)T has a covariance matrix given by K=[ 3 -1 -1 3 ] Find a transformation matrix A so that the vector Y=AX is a gaussian random vector with uncorrelated (and therefore independent) components of unity va..
A 3-phase power system consists of a wye-connected generatorconnected to the following loads, which are in parallel, through atransmission line. Load#1: Wye-connected load that consumes a total3-phase power of 3.6 kW at 0.8 power factor lag
Store the arrival times in memory locations starting from $1000.(Do this is in C. Store the results in an array and don't worry about the speci c location of the results.)
You are designing a 2.4 GHz receiver with a 140 MHz IF. System design constraints require that the local oscillator power be minimized to reduce the potential for interference to other systems as well as to reduce the receiver power consumption.
First you must give all different possible connection types for them and then, for each case, you should develop some tests that can define the connection type and calculate the current passing through the capacitors.
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd