Compute moments for the edge-column strip

Assignment Help Mechanical Engineering
Reference no: EM131397150

For the same floor system described in Problem 13-10 and the loading and material strengths given in Problem 13-7, assume the slab thickness has been selected to be 7 in.

(a) For a typical interior floor panel, calculate the immediate deflection due to live load and compare to the limit given in ACI.

(b) For the same floor panel, calculate the total deflection after the attachment of partitions and compare to the limit given in ACI for partitions that are not likely to be damaged by long-term deflections. Assume that 85 percent of the dead load is acting when the partititions are attached to the structure and assume that 25 percent of the live load will be sustained for a period of 1 year.

Problem 13-10

For the floor system shown in Fig. P13-7, assume the slab has four equal spans in the north-south direction and three equal spans in the east-west direction. Assume story heights above and below this floor are 10 ft - 0 in. Use the loading and material strengths given in Problem 13-7 and assume a slab thickness of 7.5 in.

(a) Use an equivalent-frame method to analyze the factored design moments along column line 2 and compare the results with the moments used in part (b) of Problem 13-7.

(b) Use an equivalent-frame method to analyze the factored design moments along column line A and compare the results with the moments used in part (b) of Problem 13-8.

Problem 13-8

Refer to the slab shown in Fig. P13-7 and the loadings and material strengths given in Problem 13-7.

(a) Select slab thickness.

(b) Use the direct-design method to compute moments, and then design the reinforcement for column and middle strips running east and west along column line A.

Problem 13-7

The slab shown in Fig. P13-7 supports a superimposed dead load of 25 psf and a live load of 60 psf. The slab extends 4 in. past the exterior face of the column to support an exterior wall that weighs 400 lb/ft of length of wall. The story-to-story height is 9.5 ft. Use 4500-psi concrete and Grade-60 reinforcement. (a) Select slab thickness.

(b) Use the direct-design method to compute moments, and then design the reinforcement for column and middle strips running north and south along column line 2.

(c) Check two-way shear and moment transfer at columns A2 and B2. Neglect unbalanced moments about column line 2.

173_1304c729-4031-4132-a5b8-7af8e4bb6050.png

Reference no: EM131397150

Questions Cloud

Description of scrum teams in the scrum guide : Review the description of scrum teams in “The Scrum Guide.” How are agile teams different from traditional teams? How do you think those differences can contribute to flexibility and efficiency in agile projects?
Design square spread footings for the following conditions : Service dead load is 12 kips/ft, service live load is 8 kips/ft. Wall is 16 in. thick. Allowable soil pressure, qa, is 6000 psf. F'c = 3500 psi and fy = 60,000 psi. Design square spread footings for the following conditions.
How could martha have sped up the cooling process of lasagna : Although Jeremiah did not get sick, there were several areas throughout Jeremiah's day that could have led him to a serious case of food-borne illness. Point out these areas and briefly explain why they are of concern and what Jeremiah could have ..
What is meant by positioning strategy : In the hospitality industry, most organizations are service-oriented. What is meant by automation with regard to the hospitality industry? How do you foresee automation and technology positively contributing to higher service levels in place of labor..
Compute moments for the edge-column strip : For the same floor panel, calculate the total deflection after the attachment of partitions and compare to the limit given in ACI for partitions that are not likely to be damaged by long-term deflections. Assume that 85 percent of the dead load is..
Determine ideal fourth and corresponding interquartile range : For the data in Exercise, determine the ideal fourths and the corresponding interquartile range.- Verify that the sample variance and Winsorized variance are 7.4 and 1.8, respectively.
Muslim structures and pilgrimage : Describe the main purpose of the Hajj in the Muslim faith, and identify two (2) specific aspects of the Hajj that you find fascinating or significant. Next, explain the association between Muhammad and the area of the Dome of the Rock in Jerusalem..
Devise a method for computing the sample variance : One million couples are asked how many children they have. Suppose the relative frequencies are f0/n = .10, f1/n = .20, f2/n = .25, f3/n = .29, f4/n = .12, and f5/n = .04.
Does antigone deserve our admiration for her resolve : Read "Sophocles Antigone" part of "The Greek Plays: Sixteen Plays by Aeschylus, Sophocles, and Euripides":Your task is to write a thesis-driven essay in response to follow prompt:Does Antigone deserve our admiration for her resolve and determination?

Reviews

Write a Review

Mechanical Engineering Questions & Answers

  Package design

Package Design Brief: Assume you are the packaging engineer for a large consumer products company. In this company, the Packaging Design Briefs are initiated by the marketing group and forwarded to the Package Engineering group.

  Mechanical engineering questions

Define dynamic viscosity, Determine the centroid, Pressure due to the height of liquid, Advantage of changing the liquid, Calculate the total moment about the hinge of the seal gate.

  Automatic control

DOF system and Find the differential equation describing the system

  Write a paper on boyle''s law

Write a paper on Boyle's law and describe Compression and Combustion stroke . Also explain Charles's law and illustrate SI engine and CI engine.

  Verify the law for parallelogram of forces

To Verify the law for parallelogram of forces, law for triangle of forces and law of polygon of forces. These laws are very useful to calculate unknown forces in very short time.

  Discharge pressure of the compressor

What is the discharge revised discharge pressure of the compressor.

  The Case for Global Accounting Standards

The role of IFRS in both developing and developed capital markets.

  Wind turbine

Wind turbines are becoming more and more common as a method of energy production, wind turbines by their very nature are dynamic and are subject to and create their own internal and external kinematics and kinetics.

  Advanced design methodologies

8 x product engineering and design review (week 2 – 12), ~3 pages per item which must contain a brief description of the product then delve into concepts such as materials selection, manufacturing methods, life cycle analysis, recyclability and overa..

  Design of absorption column and the cooler

Design of absorption column and the cooler. Process design of other units should be completed along with pipe sizes.

  Determine the maximum total bending moment

Determine maximum total bending moment (static plus dynamic) of the beam under steady-state conditions.

  Force of the water on the gate

Determine the magnitude of the horizontal and vertical components of the force of the water on the gate.