Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
) a three phase delta-connected generator has an internalimpedence of 0.6+j4.8. when the load is removed from the generator the magnitude of the terminal voltage is 34500V. the generator feeds a delta-connected load through a transmission line with an impedence of 0.8+j6.4. the per-phase impedence of the load is2877-j864.a) construct a single-phase equivalent circuit.b) calculate the magnitude of line current.c) calculate the magnitude of the line voltage at the terminals of the load.
The design must show all stages used in its development and must be implemented and tested in PSpice and suitable timing waveforms produced.
Let x and y be Bernoulli randon variables that take on values 1 and 0. X is distrubuted with p = 0.5. What distribution on y will maximize the Kullback-Leibler divergence (D(x||y)
A wire has a resistance of 29.7 . It is melted down, and from the same volume of metal a new wire is made that is 4 times longer than the original wire. What is the resistance of the new wire
a The cosmic background radiation has a temperature of 2.725 °K. At what wavelength is this radiation most intense b If the most intense radiation of a blackbody occurs at 1000 nm, what is its temperature
A balanced three-phase source is supplying 90 kVA at 0.8 lagging to two balanced Y-connected parallel loads. The distribution line connecting the source to the load has negligible impedance. Load 1 is purely resistive and absorbs 60 kW.
A Balanced Three-Phase Circuit is Characterized as follows: Y-Δ Connected Source Voltage in B-phase is 20
What is the equivalent (total) resistance of 100, 200, and 50 resistors connected in series What is the equivalent (total) resistance of 100, 200, and 50 resistors connected in parallel
A uniform plane E field, polarized in the x direction travels in the negative y direction in dry earth (Er = 16, Mu(r) = 1) with a phase constant Beta = pi rad/m and an amplitude of 4.0 A/m. If this field has its maximum value at t = 0, y = 2
When communicating with a geostationery satellite from earth,the distance between transmitter and receiver is approximately 35000km.assume that the friis law for free space loss is applicable and the stations have parabolic antennas
Two point charges of equal magnitude q are positioned at z= +/- d/2. (A) Find the electic field everywhere on the z axis. (B) Find the electic field everywhere on the x axis. (C) Repat steps A and B if the charge at z= +/- d/2 is -q instead of +q
calculate the capacitance of the capacitor and the inductance of the inductor. for the capacitor it's going to be 1/(j*2*pi*frequency*capacitance) and (j*2*pi*frequency*inductance) for the inductor but what are the valves for the capacitance and ..
To simulate a continuious-time system with input x(t) and impulse response h(t) using a digital system, one can first sample x(t) and h(t) to obtain x[n] and h[n] respectively and then perform a discrete-time convolution between x[n] and h[n]
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd