A 3-phase, 10 MVA, 11 kV generator with a solidly earthed neutralpoint supplies a feeder. The relevant impedances of the generator andfeeder in ohms are as under:
Generator feederPositive sequence impedance j 1.2 j 1.0Negative sequence impedance j 0.9 j 1.0Zero sequence impedance j 0.4 j 3.0
If a fault from one phase to earth occurs on the far end of the feeder, calculate
(1) the magnitude of fault current2) line to neutral voltage at the generator terminal.
A series-connected circuit has a 240-V voltage source, a 10- resistance, a 5- resistance, and an unknown resistance Rx. The voltage across the 5-? resistance is 30 V. Determine the value of the unknown resistance.
Draw the shear and bending-moment diagrams for the beam and loading shown, and determine the maximum absolute value
a 220v shunt motor driving its normal load draws an armature current of 50A. The armature resistance is 0.25ohm. determine the armature current it will draw when connected to 200V source while maintaining the armature speed and the flux per pole.
Three amplifiers with power gains of 15, 22 and 7 ate cascaded. The input power is 120 micro-W. What is the output power of the final amplifier stage
Suppose that a three-bus power system has the subtransient bus impedance matrix given below, and that the power system is initially unloaded with a pre-fault bus voltage of 0.98 pu. Assume that a symmetrical three-phase fault occurs at Bus 1, and ..
How To Three-Phase Electrical Wiring installation in a Multi-Story Building ??
A (bad) solution analogous to that in Figure E14.30(b) could be employed, requiring two circular SRs. As in the exercise above, devise a better circuit that solves this problem.
Determine the form of the particular solution for the differential equation- 2dv(t)/dt + v(t) = 5tsin(t) Then, find the particular solution. (Hint: The particular solution includes terms with the same functional forms as the terms found in the forc..
Baseball cards are two and a half inches by three and a half inches how many baseball cards. On a bulletin board that is 45 inches long by 36 inches wide
Calculate the overall heat transfer coefficient (U) for the assumed tube diameter, finshape and material. Use correlations to estimate hot-and cold-side convectioncoefficients, conduction resistance, contact resistance (if any), and fouling resist..
MATLAB to design a compensator to meet the specifications - Feedback system has an open-loop transfer function
Two one phase loads, a 5kW resistor, and a 10kVA load with a 0.707 lagging power factor are connected in parallel to a 120 V source. What is The power factor of the current supplied to the two loads by the source