Calculate the load on each transformer

Assignment Help Electrical Engineering
Reference no: EM13862585

1 A single-phase transformer is wound with 80 turns on the secondary winding and the primary supply voltage is 240 volts, 50 hertz. The minimum core flux is 0.002 Weber. Determine:

(a) the secondary voltage

(b) the primary turns

(c) the secondary load current for a primary load current of 10 amperes. 6

2 A single-phase transformer is used to reduce a 240 volt supply to 12 volts to operate a doorbell. If the primary winding has 480 turns, how many turns must be added to the secondary winding so the transformer can be used for a 30 volt doorbell?

3 A 240/32 volt swimming pool light transformer has a core loss current of 0.5 ampere and a magnetising current of 5 amperes. Use a scale of 20 millimetres per ampere to determine the value and power factor of the transformer's no-load current.

4 A 240/40 volt transformer supplies two different secondary loads. One load (a) draws a current of 12 amperes at a lagging power factor of 0.94. The other load (b) draws a current of 12 amperes at a leading power factor of 0.94. With both loads disconnected, the primary current is found to be 2 amperes at a power factor of 0.173.

Determine the primary current when both the loads are connected.

5 A 10 kVA transformer has an iron loss of 250 watts and a half-load copper loss of 80 watts.

Determine the full-load efficiency at 0.8 power factor.

6 The open circuit voltage of a transformer is 240 volts.

Determine the full-load voltage if the percentage regulation is 8%.

7 An autotransformer has a step-down ratio of 2:1 and the primary is connected to a 415 volt supply. A motor has a normal rated voltage of 415 volts and a starting current of 100 amperes. Determine, with the autotransformer in circuit:

(a) the motor terminal voltage

(b) the starting current drawn from the transformer secondary (assume that the starting current is proportional to voltage)

(c) the current drawn from the 415 volt supply

(d) the current in the common portion of the transformer winding.

8 The design requirements of a 6600 V/400 V 50 Hz single-phase core-type transformer are: Approximate emf/tum: 15 V Maximum flux density: 1.5 T

Find a suitable number of primary and secondary turns, and the nett cross-sectional area of the core.

9 Two single-phase 33 kV/11 kV transformers rated at 400 kVA and 500 kVA are connected in parallel to supply 800 kVA at a pf of 0.85 lagging. The transformers have percent impedances of 5.38% and 6.1% respectively.

Calculate the load on each transformer.

10 The input voltage, current and power to a single-phase load are measured by means of a voltmeter, ammeter and wattmeter respectively, each of these instruments being single-range type. They are connected to the lines by means of a current transformer of ratio 100:5 and a voltage transformer of ratio 50:1.

Draw a circuit diagram to show how the CT, VT and meters are connected into the load circuit. Neglecting instrument and transformer errors, calculate the load kVA and power factor if the voltmeter, ammeter and wattmeter indicate values of 200 V, 2.73 A, and 436 W.

Reference no: EM13862585

Questions Cloud

What are the key parts of a tcp or ip lan plan? : What are the key parts of a TCP/IP LAN plan?
Moving and renaming files and folders are all function of : Copying, moving, and renaming files and folders are all functions of _
Why is marketing research at the core of any marketing plan : Why is marketing research at the core of any Marketing Plan? Assuming you have started to research/think about your team Marketing Plan for the Droneport in Country X; what kind of Marketing research are you planning to use? Have you started g..
Pros and cons of main types of business organizations : Discuss the pros and cons of three main types of business organizations (sole proprietorship, partnerships, and corporations) and determine which would be the best type for the Cardigans.
Calculate the load on each transformer : Two single-phase 33 kV/11 kV transformers rated at 400 kVA and 500 kVA are connected in parallel to supply 800 kVA at a pf of 0.85 lagging. The transformers have percent impedances of 5.38% and 6.1% respectively. Calculate the load on each transfo..
Cracking password management protocols : Identify and describe any obstacles, and explain your solutions for them. Given the access policy, evaluate whether or not Extensible Access Control Markup Language (XACML) could be used to express the contextual attributes.
Compare and contrast frameworks : Compare and contrast the 3 selected frameworks
Calculate the probability of zero patients in the system : Calculate the probability of zero patients in the system (PO), the probability of one patient (P I), and the probability of two or more patients simultaneously arriving during the night shift.
Compare and contrast public and in-house cas : Compare and contrast public and in-house CAs

Reviews

Write a Review

Electrical Engineering Questions & Answers

  Design synchronous sequential ckt by flip flop excitation

Design a synchronous sequential circuit with one input line and one output line that recognizes the input string x = 1111. The circuit is also required to recognize overlapping sequence such that if the input string is x = 1101111111010

  A balanced three-phase load consists of delta-connected

A balanced three-phase load consists of delta-connected impedances in parallel with solidly grounded y-connected impedances. Express the currents Ia, Ib, and Ic flowing in the lines from the supply source toward the load in terms of the source..

  What is the rms magnitude of the voltage at the source end

A group of small appliances on a 60Hz system requires 20 kVA at 0.85 pf lagging when operated at 125V (rms). The impedance of the feeder supplying the appliances is 0.01 + j0.08 Ohms. The voltage at the load end of the feeder is 125V (rms).

  Contrast electron and hole drift velocities through silicon

contrast the electron and hole drift velocities through a 10-µm layer of intrinsic silicon across which a voltage of 5 V is imposed. Let µn = 1350 cm²/V·s and µp = 480 cm²/V·s.

  Determine what is the reactance of the inductor

A perfect inductor with L = 0.2 H is connected in series to a voltage source with: v(t) = 10cos(40pi(t) 20degrees). What is the reactance of the inductor

  Determine how many overflows will occur

The input capture option on the HCS12 is used to measure the period of a 100 Hz signal. With an E-clock of 24 MHz and no scaling, how many overflows will occur Assume the free-running timer starts at 0x0000.

  Calculate the power supplied to the 3-phase load

Three resistors are connected in delta. If the line voltage is 13.2 kV and the line current is 102.2 A, calculate the following: a. The current in each resistor. b. The voltage across each resistor. c. The power supplied to each resistor.

  Design sequence generator circuit with 4 outputs w-x-y and z

Design a sequence generator circuit with 4 outputs W,X,Y and Z. The circuit should generate the following sequence of output patterns: 0001, 0011, 1100, 1000. After 1000, the circuit should repeat the sequence starting at 0001 again.

  Implement design in logicworks and test for functions

Design a finite state machine that has an input (w) and an output(z). The machine is a sequence detector that produces (z =1). when the previous two values of (w) were (00 or 11); otherwise (z = 1). Assume the initial state is unknown past with (z..

  How suitable lan would be for implementation of application

a) draw a schematic diagram of the network showing all workstations, servers, segments and bridges (or gateways or routers or brouters). b) State which network software is used in the LAN and describe how the software facilitates the functions.

  Explain using diagram

If L=0.0053nH, C=15µF find the operating frequency of series LC circuit. What factors decides capacitance? Explain using diagram.

  Calculate the armature current-total losses in the machine

A 240kW 500 Volt 1750rpm separately excited dc generator has an overall efficiency of 94%. The shunt field resistance is 60ohms, and the rated current is 5amps. The I^2R loss in the armature is 0.023pu.

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd