A spherical droplet of liquid A and radius ro evapo- rates into a stagnant layer of gas B. Derive an expres- sion for the evaporation rate of species A in terms of the saturation pressure of species A, pA(ro) = pA,sat, the partial pressure of species A at an arbitrary radius r, pA(r), the total pressure p, and other pertinent quantities. Assume the droplet and the mixture are at a uniform pressure p and temperature T.
For calibration purposes, you've been asked to calculate the expected evaporation rate (kg/h · m2) for a test with water and air under the foregoing conditions, using the known value of DAB for the vapor-air mixture.
Water enters a 10-cm diameter pipe at a uniform velocity V, it leaves the pipe at a non-uniform velocity of u= 10(1 - r^2/0.01) m/s, where r is in meters. Using the equation derived in class (10-2-14) find the magnitude of V and the mass flow rate of..
Problems involving viscous dissipation of energy are dependent on viscosity μ, thermal conductivity k, stream velocity Uo, and stream temperature to. Group these parameters into the dimensionless Brinkman number, which is proportional to μ.
Calculate the heat load for this building which consists of 3 floors, each floor has 2 apartments, and located at Jeddah city the total volume is 2100 m3 the total area is 700 m2 suppose there are 25 people, 6 computers, 6 refrigerators, 6 ovens, 6..
air at 325 k and 70 kpa flows over the upper side of a 1-m-square plate. the upper plate is maintained at a constant
A total condenser is to be designed for condensing saturated 2-butanol vapor to form saturated 2-butanol liquid at 1 atm at the rate of 0.72 kmol/h. The saturation temperature of 2-butanol vapor at 1 atm is 99.6C. Cooling water at 25C and 1 atm is av..
The odd parity bit for all data received since the circuit was reset. This output should be 0 the clock cycle after a reset since no zeroes or ones have been received by the circuit at that point.
A power outage occurred at a water distribution pump station. Before the power outage the station was pumping with one pump at 6,000 gpm in a 18" diameter Steel Pipe
Define the main structural characteristics of a pin joint and describe an existing structure where such joints are used and why.
A mixture of air and water at a temperature of 30ºC and a pressure of 750 mmHg has a relative humidity of 75%. The wet gas is compressed to 40 psia and cooled to 20ºC. How many cubic meters of original gas were compressed if 0.75 lb of condensate (wa..
If the flow rate of the water is to be maintained at 3.15*10-3 m3/s and the water temperature remains constant at 16oc ,estimate the power rating of the motor required to drive the pump.
a rigid 2-ft3 vessel contains water originally at 150of and 5.07 percent quality. the water is then heated until its
air at 140 kpa and 27 degc is contained in the cylinder of a piston-cylinder device. at this initial position the