The nameplate on a 50-MVA, 60-Hz single-phase transformer indicates that it has a voltage rating of 8.0-kV: 78-kV. An open-circuit test is conducted from the low-voltage side, and the corresponding instrument readings are 8.0kV, 62.1A, and 206kW. Similarly, a short-circuit test from the low-voltage side gives readings of 674 V, 6.25 kA, and 187 kW.
a. Calculate the equivalent series impedance, resistance, and reactance of the transformer as referred to the low-voltage terminals.
b. Calculate the equivalent series impedance of the transformer as referred to the high-voltage terminals.
c. Making appropriate approximations draw a T equivalent circuit for the transformer.
d. Determine the efficiency and voltage regulation if the transformer is operating at the rated voltage and load (unity power factor).
a) Determine the self inductance of coil 1, L11 b) Determine the self inductance of coil 2 L22 c) Determine the mutual inductance between the two coils, L12 or L21
Design a circuit with minimum number of gates for a binary multiplier that multiplies two unsigned four-bit numbers, Using Inverters, AND, OR gates and Full Adders.
At what temperature are the two carrier densities equal?
Need to use multisim and proteus and have build the circuit diagram on multisim and proteus, also have the program written, all u need to do its simulate it and take the necessary results.
A 34.3 kg child starting from rest slides down a water slide with a vertical height of 20.3 m. (a) What is the child's speed halfway down the slide's vertical distance (b) What is the child's speed three-quarters of the way down
Determine if the following CT signal is periodic. calculate the fundamental period T0 for the CT signal: x(t) = 2cos(4*pi*t/5)*sin^2(16t/3)
The solution to Power Factor, Two single-phase loads are connected in parallel across a 415 V, 50 Hz supply. One load is rated 130 kW at a power factor of 0.75
Willy has also noticed that the power supply has a current limit that can be set. When he sets the current limit to 8 amperes, it provides exactly 8 amperes, but it doesn't overheat, so it's not shutting off all the time.
What is the power level entering the first active stage of the receiver at 1900 MHz being fed by a 25 meter coax with a loss of 20 dB/km, given that the Isotropic Receive Level is -134 dBW and the receiving station has a 1 meter radius dish
Suppose a linear circuit contains a voltage source and a current source. When the voltage source is set to 10V and the current source is set to 10 mA, the output voltage is 1V. When the voltage source is set to 10V and the current source is set to..
A three-bit Johnson counter is clocked with pulses at a 120 MHz rate. What will be the pulse frequency of the output of the last flip-flop in the chain. Ten pulses are applied to a four-bit asynchronous counter. If the counter state was 0000 befor..
A 150MW alternator generates an open-circut line-t0-line voltage of 12kV at nomial DC excitiation. When the terminals are placed in short-circuit the resulting current per phase is 8000A.
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]