Show a complete timing diagram for a 3-bit up/down counter that goes through the following sequence: 0, 1, 2, 3, 2, 1, 2, 3, 4, 5, 6, 5, 4, 3, 2, 1, 0. Indicate when the counter is in the UP mode and when it is in the DOWN mode. Assume positive edge-triggering.
Determine the current drawn from a three-phase 440 V line by a three-phase 15-hp motor operating at full load, 90% efficiency, and 80% power-factor lagging. Find the values of P and Q drawn from the line. (Hint: 1hp = 746W)
A Gaussian random process having a mean value of 2 and a variance of 4 is passed through an ideal half-wave rectifier. a) Let Xp (t) represent the random process at the output of the half-wave rectifier
1. Calculate the total (composite) load power factor, true power, reactive power and apparent power. 2. Also calculate the full-load current and the amount of capacitive KVAR needed to bring the overall power factor to .95 lagging.
A three-phase, 3.73kW, 208V, 60Hz induction motor runs at 1746rpm when it delivers rated output power. What are: a) the number of poles of the machine b) the slip at full load
A heat pump maintains a dwelling at 68 F. When operating steadily, the power input to the heat pump is 5 hp, and the heat pump receives energy by heat transfer from 55 F well water at a rate of 500 Btu/min.
Systems that operate under real time conditions need to be causal - that is, they can only process present and past inputs. When no real time processing is needed the system can be non-causal.
The power consumption of asingle-phase electric load fed from a 120 volt source representedby: P(t) = 100 (1-e-t/10) KW where t is the unit time inhours. Compute the energy consumed by the load over the period of 24 hours.
he circuit is excited by a full-wave, ac/dc SCR converter. The ac voltage (input to the converter) is 120 V (rms), and the circuit resistance is 5 Ohm. At a trggering angle of 30 degrees, the load current is continous . Calculate the following
One step in decoding a simple code without knowing the coding scheme , involves counting the number of occurrences of each character. Then, knowing that the most common letter in English is "e" the letter that occurs most commonly
Write an instruction sequence to subtract the 6-byte number stored at $800-$805 from the 6-byte store a $810-$805, and save the result at $900-$905
Suppose we have a causal LTI system with rational system function H(s). We don't know H(s), but we do have the following information: i. When the input to the system is x(t) = u(t), the output y(t) is absolutely integrable.
A 75 ohms lossless air transmission line at 3 GHz is terminated in a load of (300-j400) (a) What is the load reflection coecient (b) Determine the impedance at 2.5 cm, 5.0 cm, 7.5 cm and 10 cm from the load.