Consider an 8-L evacuated rigid bottle that is surrounded by the atmosphere at 100kPa and 17 degrees C. A valve at the neck of the bottle is now opened and the atmospheric air is allowed to flow into the bottle. As soon as the pressure in the bottle reached 100kPa the valve is closed. What is the temperature of the air that is in the bottle at the end of this filling process? (bottle is insulated)
a building for which the heat transfer rate through the walls and roof is 1350 btuh per degree temperature difference
a copper specimen is cold worked at room temperature and annealed at 100-400c. draw schematic sketches showing how
An ogee spillway of a gravity dam is to be modeled using water. The spillway section is 40 feet high, its crest length is 60 feet and the maximum discharge is 3,000 CFS when the head on the crest of the spillway is 5 feet. Using a model scale of 1:10..
two moist air streams flow into a modified cooling tower to cool liquid water from 120 f to 75 f. the first moist air
a certain superinsulation material having a thermal conductivity of 2 x 10-4 wm.c is used to isulate a tank of liquid
a steam turbine has an inlet pressure of 1200 kpa and temperature of 400 degc. the steam exits the turbine at a
a shaft is a circular cross sectional with diameter of 1.5 is subjected to loading of bending mz 5000 lb-in and a
A refrigerating plant operating between temprature limit of 253k and 307k provides 4.5kJ/s of refrigerating effect. If the refrigerating efficiency of the plant is 0.76. calculate the power required to drive the plant.
in each case locate the state on sketches of the t-v and p-v diagrams.a four kg of water at 100c fill a closed
in the following experiment a constant-pressure calorimeter containing 100 ml of h20 is used.the initial temperature of
the inlet to a nitrogen compressor is a pipe of 5cm internal diameter its outlet is a pipe of 2 cm internal diameter.
a pressurized tank is nominally at 205 degree c. the density determination must be within 0.5 to be useful. if the