Analyze each of the following control systems and determine whether they have self-regulation, what the process load would be, what would constitute a transient, and whether a process lag would be expected:
a. A home air-conditioning system
b. The cracker-baking system
c. The level-control system
The armature of a simple DC generator is rotating at a speed of 188.5 rad/s. If the armature consists of 3 turns per coil, and a current is flowing in the field coils such that the field coils produce a flux of 0.0333 Wb
Write a The term paper projects are: ELECTROENCEPHOLOGRAPHY, ELECTROCARDIOGRAPHY, ELECTRONIC PROSTHESIS/PROSTHETICS, REMOTER SURGERY and MEDICAL ALERT DEVICES.
A machine operates at 0·8 p.f. lagging and has a monthly demand of 750 kVA.- Calculate the annual saving effected by the use of capacitors.
Calculate the reactive power and the current supplied to the load and sketch a phasor diagram for this load condition, showing all circuit voltages and currents.
A touch sensor base on a piezoresistor built into a micromechanical cantilever made of silicon is cnnected in a Wheatstone-bridge configureation with a Vo = 1 volt. If L = 1.44cm and W = 1 cm
Find the Wiener-Hopf equation for the optimum (in the minimum mean square error (MMSE) sense) filter. - Find the form of the Wiener filter.
Use MATLAB to generate a 256x256 black image (0 values) with a 1-valued central block (white square) of 64x64 size. Analytically or graphically define/derive how to determine the rotation angles and different coordinates systems.
The 24-bit data field of a packet is given by 0xBC603F. The packet contains a CRC with the generator polynomial given by X 3+X+1 a) Find the CRC checksum. Provide the complete code-word including the checksum in hex.
Determine the transfer function of the overall integrator.
Motor running at normal speed unloaded; the armature current was 22.5 A, when the applied voltage was 550 V; allow 2 V for brush contact drop and 1 % of the rated output of 400 kW for stray-load losses.
Devise a system that will convert this temperature range into an 8-bit digital word with conversion from 00H to 01H at and the change from FEH to FFH occurring at 350°C. An ADC is available with a 2.500-V internal reference.
Develop a control system to fill a container with water after it is emptied through a stopcock at the bottom. The system must automatically shut off the water when the container is filled.