An open feedwater heater operates steadily with 30 kghr of

Assignment Help Mechanical Engineering
Reference no: EM13344433

An open feedwater heater operates steadily with 30 kg/hr of liquid water entering one inlet at 40 °C and 700 kPa. Water vapor enters a second inlet at 200 °C and 700 kPa. Saturated liquid exits with a pressure of 700 kPa. The dead state temperature and pressure is 20 °C and 100 kPa, respectively. (a) Draw and label a schematic of the system. (b) Determine the mass flow rate (kg/s) of water vapor needed and (c) the rate of exergy destruction (kW) 

Reference no: EM13344433

Questions Cloud

A collector modulated transmitter has a supply voltage of : a collector modulated transmitter has a supply voltage of 48 v and an average collector current of 600 ma. what is
This is a solid mechanics question involving a rigid bar : what does it mean when a steel cable is required to have a factor of safety of at least 5 against its ultimate load?
Oxygen is released until the volume is 100 l how many moles : a sample containing 4.80 g of gas has a volume of 15.0 l. pressure and temperature remain constant. what is the new
Draw the class diagram for the classes required in a : draw the class diagram for the classes required in a basic microwave oven. the system should be able to set the
An open feedwater heater operates steadily with 30 kghr of : an open feedwater heater operates steadily with 30 kghr of liquid water entering one inlet at 40 degcnbspand 700 kpa.
Calculate the maximum mass in grams of h2s that can form : calculate the maximum mass in grams of h2s that can form when 155 g aluminum sulfide reacts with excess water according
The heat of fusion of ice the heat associated with ice : an ice cube of mass 8.5 is added to a cup of coffee whose temperature is 95 and which contains 130 of liquid. assume
The standard free energy of activation of a reaction a is : the standard free energy of activation of a reaction a is 86.2 kj mol-1 20.6 kcal mol-1 at 298 k. reaction b is one
An inductor motor is connected to a 220 v 60hz supply and : an inductor motor is connected to a 220 v 60hz supply and drews 5.0a at 0.85 lag power factor. 1. what value of

Reviews

Write a Review

Mechanical Engineering Questions & Answers

  Find the cycle cop

An air conditioner in the airport of Timbuktu runs a cooling system using R-410a with a high pressure of 1500 kPa and a low pressure of 200 kPa. It should cool the desert air at 45 degrees C down to 15 degrees C. Find the cycle COP. Will the syste..

  What is the effect of quenching on transition temperature

what is the effect of quenching on the transition temperature and toughness for the mild steel ?

  What is the inner tube surface temperature at the outlet

What is the inner tube surface temperature at the outlet, where fully developed conditions may be assumed?

  Show that the total true strain is the sum of the true

Show that the total true strain is the sum of the true strains in each step, that is the true strains are additive. Show that using engineering strains, the strain for each step cannot be added to obtain the total strain.

  Determine the speed at which it strikes the ground at b

the snowmobile is traveling at 10m/s when it leaves the embankment at A.determine the speed at which it strikes the ground at B and its maximum acceleration along the trajectory AB.

  Compute the maximum bending stress at mid-span

Calculate the maximum bending stress at mid-span, and, for the same section, locate the neutral axis. Neglect the weight of the beam

  How the lubricants reduce the friction

How the lubricants reduce the friction and wear characteristics of the parts in contact?

  An ideal vapor-compression refrigeration system operates

An ideal vapor-compression refrigeration system operates at steady state with Refrigerant 134a as the working fluid. Superheated vapor enters the compressor at 30 lbf/in2, 20F, and saturated liquid leaves the condenser at 140 lbf/in2. The refriger..

  Determine the exit temperature

Air at 90 kpa and -7 C enters an adiabatic diffuser steadily with a velocity of 180 m/s and leaves with a low velocity at a pressure of 100 kpa. The exit area of the diffuser is 5 times the inlet area. Determine (a) the exit temperature and (b) th..

  What is the temperature cm from the base

What is the temperature 7 cm from the base if the rod is made of a) pure zinc b) lead c) pure gold. Which will be the hottest at this point?

  Explain the compression ratio of an air-standard otto cycle

The compression ratio of an air-standard Otto cycle is 9.5. Prior to the isentropic compression process, the air is at 100 kPa, 17 C, and 600 cm2

  What is the flow rate required to cool and maintain

what is the flow rate required to cool and maintain 0.5 x 0.5 x 0.5 m3 volume of air at 297 K to 199 K, using nitrogen at 199 K

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd