Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
An adiabatic heat exchanger is used to heat cold water at 8°C entering at a rate of 3 kg/s using hot air at 150°C entering with the same mass flow rate. If the air’s exit temperature air is 30°C, what is:
The water’s exit temperature, calculated using both constant room temperature specific heats and temperature average specific heats (specific heats at average of inlet and exit temperatures)
The specific heat transfer rate from the air to the water, calculated using both specific room temperature and average heat assumptions.
Discuss briefly (no more than three or four sentences) whether or not you think there is any reason to prefer one method of determining specific heats over the other in this case. Be sure to justify your answer using quantitative results (% differences, etc.).
Notes:
Assume constant room temperature specific heats for the water flowing through the heat exchanger and average temperature specific heats for the air.
Consider the cylindrical weir of diameter 3 m and lenght 6m.if fluid on the left has specific gravity of 1.6,and on the right has a specific gravity of 0.8,find the magnitude and direction of the resultant force
electronic components mouted on a flat plate are cooled by convection to the surroundings and by liquied water
Calculate the service factor for a simple lawn mower driven by a two stroke engine. The lawn mower is used by a service for 8 hours per day. If the lawnmower normally operates at 1200 rpm and 2 hp what is the starting torque?
an engineering student considers using a fan as a levitation demonstation. she plans to face the box-enclosed fanso the
a particular coal has the following mass analysis inert ash 10 percent nitrogen 2 percent oxygen 12 percent sulfur 1
a heat pump utilizes a well-insulated compressor to compress r-134 from a saturated vapor at 160 kpa at a rate of 0.85
an ice chest is constructed of 0.4 mm thick plain-carbon steel plate a 1.9 cm thick layer of styrofoam k0.033 wm c and
Laboratory measurements of water flowing across a flat plate indicate a local shear stress of 2.3 Pa. the free-stream velocity of the water is 5 m/s. If the free-stream & plate temperature are 15 C & 60 C, respectively, what is the local heat flux?
you are building a small hydroelectric generator for a hospital in a remote village. the hospital needs approximately
two solid cylinders rods AB and BC are welded together at B and loaded. determine the magnitude of the force P for which the tensile stress in rod AB is twice the magnitude of the compressive stress in rod BC?
a valve in a cylinder has a cross sectional area of 11 cm2 with a pressure of 735 kpa inside the cylinder and 99 kpa
consider a hypothetical phase diagram in which component ame lts at 900c component b melts at 1000c and there is an
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd