A complex voltage waveform which has an rms value of 240 V contains 30% third harmonic and 10% fifth harmonic, both of the harmonics being initially in phase with each other. (a) Determine the rms value of the fundamental and each harmonic. (b) Write down an expression to represent the complex voltage waveform if the frequency of the fundamental is 31.83 Hz.
What is Average value in AC circuit?
An induction load consisting of a bank of induction motors consumes 50 kW at a power factor of 0.8 lagging from a 220-V (rms), 60-Hz single phase source. By placing a bank of capacitors in parallel with the load, the resultant power factor is to b..
a single phase 100 kVA, 1000/100 V transformer gives the following test results: Open Circuit test: 100V, 6.0 A and 400 W Short Circuit test: 50V, 100A and 1800W At what load will maximum efficiency occur
A series combination of two capacitances, valued 0.2 μF and 0.6 μF initially discharged, is charged to 10V. find the charge and energy stored in each capacitance.
Design a counter whose count sequence is all prime numbers greater than 4 less than 55. Provide the excitation equations for the FlipFlops.
A battery is charged. The relationship between the charging current, i amperes and the time, t hours passed, is given by the formula:
Derive and graph the electric field based on V-bi( built in Potential). Derive the depletion width (w) from built in potential and equilibrium charge equation. graph Depletion width and E-feild in forward bias.
Assume that a fault occurs on the high-voltage side of transformer T2 in the power system shown in Figure P13-2. Make the assumption that the generator is operating at rated voltage, and that the power system is initially unloaded. Calcu..
A 3-phase transmission line series load of 2000MVA, .8 p.f. lag at 735 kv. The ABCD parameters of the line are : A = .8746 =D, B = j128.33Ω, C = j.0018315 (s). Calculate Vs, Is, voltage regulation and efficiency of the line.
The power dissipated in the resistor R0 is 89 W when connected to a 10V source. Find the total dissipated power if 3 resistors identical to R0 are connected in series to a 10V source.
A single-phase, 60-Hz power will be transmitted through the transmission line Each subconductor's radius is 10 cm. There are two configurations, the first one is setting subconductors A and B as a bundle, and C and D as another bundle
Any causal signal x(t) having a Laplace transform with poles in the open left s plane (i.e. not including the jO axis)has, as we saw before, a region of convergence that includes the jO axis, and as such its Fourier transform can be found from its..