Data and control context diagrams of alarm control firmware

Assignment Help Other Engineering
Reference no: EM13911682

A low cost DIY wireless security system enables a homeowner to install the system without running cables around their house. It consists of a mains-powered (and battery-backed-up) control panel with a simple keypad, built-in sounder, LCD output display, and voice dialler. Battery powered wireless PIR sensors and a wireless alarm siren are also included in the package.

When the system is first installed (and at any future change), the homeowner can configure the system via its control panel. This configuration process involves 3 stages - pairing devices, assigning an emergency contact number, and setting a secret PIN:

1. The homeowner "pairs" all of the wireless sensors and alarm siren with the control panel, assigning each a zone number and optional description text. The user selects pairing mode, and then selects either a zone number, or the wireless siren. If they select a zone number, they can (optionally) enter additional descriptive text via the keypad, and then confirm. The pair operation then begins.

For each pair operation/zone number, the control panel broadcasts a pair request on the sensor frequency for 60 seconds.

The user then presses the "pair" button on the appropriate sensor or siren the user wants to assign, which causes the device to respond to the "pair" broadcast and identify itself to the control panel. If no devices respond in the 60 seconds, the panel returns to configuration mode.

If a device is successfully paired, the panel stores this zone data (number and description) along with a unique key for each device in onboard non-volatile memory. This allows the control panel to communicate securely with each peripheral individually by sending and receiving data as follows:

2. The homeowner can then enter an emergency contact number, which is also stored in the panel's onboard non-volatile memory.

3. Finally, the homeowner must programme a secret PIN which is used to arm and disarm the system. This is also stored in the panel's onboard non-volatile memory.

The PIR sensors, once paired, only transmit in the following circumstances to save power, and are otherwise idle:

1. If they detect motion, they send the encrypted data key to the control panel identifying themselves and a special code to indicate they have detected motion.

2. If they detect their batteries are running low, they send the unique encryption key and a special code to indicate the low battery state.

When the system is operating, its normal state is idle/disarmed. The panel display shows "Ready". During idle mode, the control panel will only display a different message if it receives a battery low message from a sensor. This message will identify the zone number (and description if available) with the low battery status. It will also "chirp" its internal sounder once every 5 minutes to alert the user. The user can acknowledge this alert with the keypad, which will stop the regular chirping.

When the user enters their secret PIN, they are prompted to confirm that they wish to arm the system. If they do, the system enters armed mode. The control panel displays "Armed". During armed mode, if the system receives a PIR motion message, it will enter alarm mode.

During alarm mode, it will display "ALARM!" on its LCD, sound its built-in sounder and will instruct the wireless siren to sound by sending it an encrypted "alarm sound" signal.

The wireless siren will sound for 15 minutes and then automatically silence itself, unless it receives an encrypted "alarm stop" signal from the panel in the meantime - in which case it will stop sounding immediately.

If the system continues in alarm mode for 90 seconds without being disarmed, the panel dials the stored emergency number and plays an automated message. If the connection fails (e.g. line busy, no dialtone), the number is redialled every 20 seconds until a connection is made (or the alarm is cancelled)

During alarm mode, if the secret PIN is entered, the system disarms and displays zone information about the zone that caused the alarm on the panel. It then returns to idle mode.

Apply the Requirements and Architecture Models to perform the analysis and design of the alarm control software described above (you can make - and should document

- necessary assumptions), and document all results obtained from each of the following tasks:

(1) Define the data and control context diagrams of the alarm control firmware.

(2) Define data flow diagram DFD 0 which shows at least four different processes, and its corresponding control flow diagram CFD 0.

(3) Define process and control specifications based on DFD 0 and CFD 0 produced in (2); the latter including any timing specification deemed necessary.

(4) Enhance the diagram DFD 0 produced in (2).

(5) Define architecture flow diagram AFD 0.

(6) Define the traceability matrix.

Reference no: EM13911682

Questions Cloud

Expected enthalpy change for the decomposition : Calculate the expected enthalpy change for the decomposition of one mole of PCl5(g) shown in equation 3 (EQ 3). Calculate the expected enthalpy change for the decomposition of 10.50 g of PCl5(g) shown in equation 3 (EQ 3).
Using a present value table your calculator or a computer : Congratulations! You have just won $500 million in the largest Power ball jackpot payoff ever! You will receive payments of $25,000,000 per year for the next 20 years.
Solutions of ammonium phosphate : Write the balanced molecular equation for each reaction and the net ionic equation? Solutions of ammonium phosphate and lithium hydroxide are mixed
What do you think of the claim : Consider Exercise 5.55, and find P(x 17) if the stain removal product's claim is correct. If x actually turns out to be 17, what do you think of the claim?
Data and control context diagrams of alarm control firmware : Define the data and control context diagrams of the alarm control firmware and define data flow diagram DFD 0 which shows at least four different processes, and its corresponding control flow diagram CFD 0.
Cash flows will occur in erewhon-are expressed in dollars : Anderson International Limited is evaluating a project in Erewhon. The project will create the following cash flows: All cash flows will occur in Erewhon and are expressed in dollars. In an attempt to improve its economy, the Erewhonian government ha..
Calculate the amount that should be recorded : Crow's cost of moving and installing the machinery totaled $4,800. The following data are available:
A decrease in the sales of a current project : A decrease in the sales of a current project because of the launching of a new project is
Formulate a linear programming model for this given problem : Lakeside Boatworks n planning to manufacture three types of molded fiberglass recreational boats-a fishing (bass) boat, a ski boat, and a small speedboat. Formulate a linear programming model for this problem

Reviews

Write a Review

Other Engineering Questions & Answers

  Evaluate evidence that would specify the existence

Evaluate evidence that would specify the existence of a risk or risks - Analyse the implications of the risk and the effect on life, property and activities

  What control signals does the microcontroller send out when

8. a in the normal expanded wide mode or the normal expanded narrow mode the mc9s12dp256b microcontroller can fetch

  Draw a ds1 frame and label it in detail

What is the data rate of a single channel on a T1 connection that does not use bit robbing?

  Which car was going faster

Each driver claimed that he was going at the speed limit of 30 mi/h and that he tried to slow down but couldn't avoid the crash because the other driver was going a lot faster. Knowing that the weights of cars A and B were 3600 lb and 2800 lb, res..

  Calculate the volumetric flow rate

Calculate the volumetric flow rate and the mass flow rate and determine the average flow velocity of the air and the air quantity flowing

  Estimate the local heat transfer

Liquid ammonia is heated as it flows at a mean velocity of 2 m s-1 through a circular pipe. The pipe, which has an internal diameter of 75 mm, is at a uniform temperature of 27°C, and the ammonia at a section 1.2 m from the inlet to the pipe has a..

  Coefficient of friction between tires and pavement

A motorist traveling at a speed of 108 km/h suddenly applies the brakes and comes to a stop after skidding 75 m. Determine

  The location will be identified in the feasibility

group 5 will be starting up a fictitious military aviation maintenance department. it was identified that a unit was

  Find the ultimate bod of the river water

Environmental engineering, CEE 357 Winter 2014. HW#6 Assignment: -  Find the ultimate BOD of the river water as it enters the lake. Find the value of the rate constant for BOD utilization in the river, k d,riv .

  Summary of political and legal issues of robotic surgery

Summary Political and Legal issues of Robotic Surgery? Summary Identify and explore What the Psychological considerations and sociological effects when having or doing Robotic Surgery?

  Calculate the corresponding values

(a) Derive the formulas for the optimum powers P1, P2, and P3 allocated to the three sub channels of frequency bands (0, W1), (W1, W2), and (W2, W). (b) Given that the total transmit power P = 10, l1 = 2/3 and l2 = 1/3, calculate the corresponding..

  What is the optimal production plan for jumbo

What is the optimal production plan For Jumbo. assuming no promotion by either Jumbo or Shrimpy'? What are the annual profits for Jumbo?

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd