Relative humidity passes over the cold evaporator coil

Assignment Help Mechanical Engineering
Reference no: EM13717603

Air at 1 atm 30 C and 80% relative humidity passes over the cold evaporator coil of an air conditioner at constant pressure. The air and condensate leave the coil at 18C. The moist air flow rate is 0.02 kg/s. using the psychrometric chart determine the following:

i) The dry air mass flow rate (kg/s)

ii) The condensate mass flow rate (kg/h)

iii) The heat transfer from the moist air (kJ/s)

Reference no: EM13717603

Questions Cloud

Solve the equations of motion using rectangular coordinates : To set up and solve the equations of motion using rectangular coordinates. The 3-kg collar shown has a coefficient of kinetic friction μk=0.205 with the shaft. The spring is unscratched when s=0 and the collar is given an initial velocity of v0=15.1..
Calculate the initial rate of cooling : A 0.025 m thick flat plate having a 20 cm X 20 cm cross section is made of plain carbon steel (k=30 W/mC), alpha=32.7 x10^-7m^2/s). The initial plate temperature is 727C. it is cooled by blowing 27C air over the top surface of the plate at 30 m/s; th..
The dry air mass flow rate entering the mixing chamber : Hot, moist outside air passes over a cooling coil, from which it exits in a saturated state at p=14.7lbf/in^2 and T=65F. The air is then mixed adiabatically with room air at p=14.7lbf/in^2, T=75F, phi=25%.
For a control volume enclosing the heat exchanger : Saturated water vapor at 100 kPa enters a counter flow heat exchanger operating at steady state and exits at 20C with a negligible change in pressure. Ambient air at 275 K, 1 atm enters in a separate stream and exits at 290 K, 1 atm.
Relative humidity passes over the cold evaporator coil : Air at 1 atm 30 C and 80% relative humidity passes over the cold evaporator coil of an air conditioner at constant pressure. The air and condensate leave the coil at 18C. The moist air flow rate is 0.02 kg/s.
The dry air mass flow rate and water vapor mass flow rate : At a certain location in a duct, moist air at 35 C, 125 kPa and a relative humidity of 50% flows at a volume flow rate of 50 m^3/s. using tabular data, determine the following: i)the humidity ratio ii)the dry air mass flow rate (kg/s) iii) the water ..
Using the heat pumps instead of the heaters : A house is kept at 22oC in the winter by means of electric heaters. On a cold day, the heaters are on for 18 hours and use an average power of 5 kW. How much power would be saved if a heat pump with a COP of 2.0 was to be used instead?
Design the svaj curves for the follower using polynomials : Equally spaced parts, with the distance between the parts being 10 inches, are coming on a conveyor belt. A machine tool has to operate on the part for 1 second as the part is moving on the conveyor. The speed of the conveyor belt is 5 in/second.
Reversible power cycle operating between hot-cold reservoirs : The thermal efficiency of a reversible power cycle operating between hot and cold reservoirs is 20%. Evaluate the coefficient of performance of a reversible refrigeration cycle operating between the same two reservoirs.

Reviews

Write a Review

Mechanical Engineering Questions & Answers

  Package design

Package Design Brief: Assume you are the packaging engineer for a large consumer products company. In this company, the Packaging Design Briefs are initiated by the marketing group and forwarded to the Package Engineering group.

  Mechanical engineering questions

Define dynamic viscosity, Determine the centroid, Pressure due to the height of liquid, Advantage of changing the liquid, Calculate the total moment about the hinge of the seal gate.

  Automatic control

DOF system and Find the differential equation describing the system

  Write a paper on boyle''s law

Write a paper on Boyle's law and describe Compression and Combustion stroke . Also explain Charles's law and illustrate SI engine and CI engine.

  Verify the law for parallelogram of forces

To Verify the law for parallelogram of forces, law for triangle of forces and law of polygon of forces. These laws are very useful to calculate unknown forces in very short time.

  Discharge pressure of the compressor

What is the discharge revised discharge pressure of the compressor.

  The Case for Global Accounting Standards

The role of IFRS in both developing and developed capital markets.

  Wind turbine

Wind turbines are becoming more and more common as a method of energy production, wind turbines by their very nature are dynamic and are subject to and create their own internal and external kinematics and kinetics.

  Advanced design methodologies

8 x product engineering and design review (week 2 – 12), ~3 pages per item which must contain a brief description of the product then delve into concepts such as materials selection, manufacturing methods, life cycle analysis, recyclability and overa..

  Design of absorption column and the cooler

Design of absorption column and the cooler. Process design of other units should be completed along with pipe sizes.

  Determine the maximum total bending moment

Determine maximum total bending moment (static plus dynamic) of the beam under steady-state conditions.

  Force of the water on the gate

Determine the magnitude of the horizontal and vertical components of the force of the water on the gate.

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd