A unity feedback position control system has a plant,
\(G(s) = \frac{10}{s(s + 1)}\)
It is desired to have the damping ratio, zeta = 0.5 and natural frequency, omega_n = 3 rad/sec. Design a phase-lead compensator by:
(a). placing the compensator or zero on the real axis right under the desired closed-loop pole.
(b). placing the compensator or zero such that it will cancel the open-loop pole at -1. For both compensators you design, show the corresponding closed-loop transfer functions and compare the transient responses (P.O. and Ts). Also, compare the steady-state errors when a unit ramp input is applied to the system.
A delta connected load consists of three identical impedances Z=45 at 60 degrees per phase. It is connected to a three phase, 208-V source by a three phase feeder with conductor impedance Zfeeder=(1.2+j1.6) Ohms per phase.
Each start/stop station contains one NO start pushbutton and one NC stop pushbutton.
A 10 kHz signal modulates a 500 MHz carrier, with a modulation index of 2. What are the maximum and minimum values for the instantaneous frequency of the modulated signal
What is the value of RTH?
When the starter motor, which draws 90A, is running the terminal voltage drops to 11V. What is the internal resistance of the battery What percentage of the chemical power is delivered to the starter motor
A single-phase, half-wave SCR circuit is used to control the power consumption of an inductive load. The resistive component of the load is 5 Ohm. The source voltage is 120 V (rms). When the triggering angle is adjusted to 60 degrees
Block diagram and equations for control system water fill, Develop a control system to fill a container with water after it is emptied through a stopcock at the bottom
Develop the Datapath; draw it under VISIO for this java code : input . x - the abscissa at which the linear interpolation is to be evaluated xi[]- the arrays of data abscissas yi[]- the arrays of data ordinates imax- size of the arrays xi[] and yi[]
Power Systems Theory Definitions and Formulas, Define, (a) The fault level of a system or unit in a system, (b) base MVA
The waveform output by the signal generator in part (b) is changed so that the rectangular pulses have the same width but no longer are periodic. They occur at random intervals of time. Explain in words how the display on the spectrum screen would..
Rate at which succesful packets arrive at network node, After traversing a wireless filled channel packets arrive at a networks node according to a Poisson process with rate Lambda
Prompt the user to enter a letter indicating Celsius or Fahrenheit C or c indicates that temperature entered is in Celsius. F or f indicates that temperature entered is in Fahrenheit.
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd