A 3-phase synchronous generator rated at 75 MVA, 13.8 kVline-to-line is connected to a power system that has a Thevenin equivalent of j0.23 per unit at 1.0 per unit voltage. The synchronous reactance of the generator is j1.35 per unit. Neglect armature resistance, armature resistance equals zero ohms. Both perunit impedances were calculated on the base MVA rating of thegenerator which is 75 MVA.
A) Determine the maximum power in MW transferred to the system when the internal voltage (Ea) of the generator is 1.10 perunit.
B) Assume the generator is being operated with constantexcitation, determine the power transferred to the system in MWwhen the power angle (δ) is adjusted to 30 degrees and theThevenin equivalent voltage drops to 0.9 per unit.
A capacitor in an RC circuit with R = 5.00 ohm and C = 6.00 mF is being charged. What is the time required for the capacitor voltage to reach 86.5 percent of its steady-state value
the arrival rat of cars at a toll plaza is 50 cars per hours. There are three boothes serving an a verage of 20 cars per hour. Assume an exponential for service time and a poisson distribution for arrival time.
A voltage source V = 119
A wire is stretched between two posts. Another wire is stretched between two posts that are twice as far apart. The tension in the wires is the same, and they have the same mass. A transverse wave travels on the shorter wire with a speed of 281 m/..
Given the function 10sin^2(10t) Find the fundamental frequency and period. Find the exponential and trigonometric coefficients of the Fourier Series. so T=pi/10. f is 20
Let y[n] = Odd{x[n+1]}, where Odd{f[n]} takes the odd part of f[n]. Determine if this system is a. Linear b. Time invariant c. Causal For each part, either show proof that the property holds or show an example that it does not.
Consider an industrial load that absorbs 40 kW of power with power factor 0.8 lagging from a 60-Hz transmission line of voltage VL= 240
Write the logic equation for Y in terms of A,B,C that solves this problem, and draw the gate-level diagram.
At a temperature of 770 C find the resistivity of ptype Si with Na= 1015/cm3. For the doped Si at the given temperature assume μn=1000cm2/V.s and μp = 350cm2/V.s.
A uniform magnetic field is applied perpendicular to the plane of a 60-turn circular coil with a radius of 6.0 cm and a resistance of 0.60 ohms. If the magnetic field increases uniformly from 0.20 T to 1.8 T in 0.20 s
If voltage and resistance are measured as a means of indirectly measuring power, show again that if the relative uncertainties in the direct measurements are +2%, that the relative uncertainty in the indirectly measured power will be +6%.
design a 4-bit serial adder (VHDL code or schematic) which includes two shift registers and a single full-adder to perform the following functionality with proper timing controls. Two 4-bit inputs A and B will be set by eight switches on your Xili..
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd