An air standard dual cycle operates with a compression ratio of 15. At the beginning of the compression the conditions are 17°C, 0.95 bar, and 3.8L. The amount of heat added is 6.3 kJ, of which one-third is added at constant volume and the remainder at constant pressure. Calculate
(a) the energy transfer for each of the components [kJ/kg],
(b) the pressure after the constant-volume heat addition process [bar],
(c) the temperature before and after the constant-pressure heat addition process [°C],
(d) the temperature after isentropic expansion[°C], and
(e) the thermal efficiency of the cycle [%].
a household hot water system heats water only as it is needed. the water enters the electric heater at 60f and is
a mass of 0.2 kg of saturated refrigerant-134a is contained in a piston-cylinder device at 200 kpa. initially 75 of the
a container with volume 213 cubic cm is heated and allowed to expand to 1.44 times the original volume. as the
nitrogen gas is heated in a steady-state steady-flow process. the inlet conditions are 550 kpa 35degc and the exit
a water system is designed to produce drinking water in arid climates. it takes air at 90 degrees f 29.7 inhg and 95
a steady flow compressor is used to compress helium from 100 kpa and 20 degrees celcius at the inlet to 1400 kpa and
the university of toledo college of engineerings sae car is powered by a 45 hp 3450rpm single cylinder honda 4-cycle
a hydrogen tank 25 cm in diameter and 80 cm in height is charged to 150 atmospheres at room temperature 25 c. a
a completely reversible heat pump produces heat at a rate of 300 kw to warm a house maintained at 24degrees c.the
in measuring the strains applied to a symmetrical i beam a full bridge is used. two strain gages are attached to the
A rigid tank contains water vapor at 200 degrees celcius and unknown pressure. When the tank is cooled to 150 degrees celcius, the vapor starts condensing. Estimate the initial pressure in the tank.
a rigid well insulated container is outfitted with a moveable but frictionless partition that separates two sides but