With this particular connection can the rated power for the primary side be supported bythe secondary side? If not, why and how could the transformer be changed to supportrated power without changing the voltage characteristics of the set-up?
For Rate Power: 5KVA
Rate Voltage: 120/240 : 120/240
Rate Frequency: 60Hz
Design a full-wave bridge rectifier circuit to deliver 10 volts de with less than 0.1 volt (pp) ripple into a load draWing up to 10mA. Choose the appropriate ac input voltage. assuming 0.6 volt diode drops.
design an arithmetic incrementer/decrementer circuit. Your circuit will recieve a 3-bit binary number (A) as input to produce an output which is either A+1 or A-1 depending upon the command input (ID).
A baseband signal has frequencies from near dc to 4 kHz. To ensure ease of recovery, the signal is to be sampled at a rate 25 percent greater than the theoretical minimum. Determine the time interval (in ms) between successive samples.
Use rail voltages of +/-15V. Sketch the circuit diagram and the voltage transfer characteristic (Vout vs Vin) Discuss how you chose the values of the components and comment on how accurately you think you can achieve the specification.
A labor intensive process has a fixed cost of $338,000 and a variable cost of $143 per unit. A capital intensive (automated) process for the same product has a fixed cost of $1,244,000 and a variable cost of $92.50 per unit.
A Si p+-n junction has the following parameters at 300K: taup = taug = 10-6 s, ND=1015 cm-3, and NA=1019 cm-3. Plot diffusion current density, generation current (Jgen) and total reverse current (JR) as a function
(i) Draw a diagram of the loads. Determine: (ii) The apparent power (kVA), active power (kW) and reactive power (kVAr) of each of the three loads. (iii) The total apparent power kVA, total active power (kW) and the total reactive power (kVAr) of the ..
write a program that would send out through the serial port an array of twenty bytes of data( need a FOR loop) stored in memory locations starting from 30H( must use a ponter) with even parity added as the ninth bit.( skip baud rate).
1. The charge flowing in a wire is plotted in the Figure below. (a) Write the expressions for q(t) as a function of time? (b) What are the corresponding expressions for i(t)?
What are the applications,classifications,design,energy conversion principles involved,maintenance and fault of compressors
Draw the individual and combined impedance (X pu) diagrams to a base of 10 MVA for the units and system - What would be the effect on the fault level of replacing the unit - Determine the pu impedance and the reactance of the interbus reactor for th..
Assume the initial state is unknown past with (z = 0). Implement the design in "Logicworks" and test for the properfunction. Use a binary switch to simulate the input. The output maybe implemented with a binary probe or an LED.