Determined to reduce the $7 per week cost associated with heat loss through their patio window by convection and radiation, the tenants of Problem 9.18 cover the inside of the window with a 50-mm-thick sheet of extruded insulation. Because they are not very handy around the house, the insulation is installed poorly, resulting in an S = 5-mm gap between the extruded insulation and the window pane, allowing the room air to infiltrate into the space between the pane and the insulation.
(a) Determine the window heat loss and associated weekly cost with the ill-fitting insulation in place. The insulation will significantly reduce the radiation losses through the window. Losses will be due almost entirely to convection.
(b) Plot the heat loss through the patio window as a function of the gap spacing for 1 mm ≤ S ≤ 20 mm.
Using the steam tables estimate cp in (kj/kg k) , for super heated steam and 0.1 Mpas and 700deg c
An engineer is designing a control system for a chemical process with reagent concentration as the sole control variable. After determining that the system is not controllable, why is it impossible for him to control all the modes of the system by..
The horsepower output from the prime mover to drive the generator at this load.
The lower flammable limit (LFL) of methanol in air is 6.0 mole%. Calculate the temperature at which the equilibrium percentage of methanol vapor in a saturated methanol-air mixture would equal the LFL. (This temperature is a rough estimate of the ..
For a certain process, the maximum allowable pressure is 0.20 torr. If a D65 rotary vane pump is used and conductance losses in the vacuum system can be ignored; what is the maximum permissible inlet flow in standard cubic centimeters per minute?
If a 500-hp, 90% efficient synchronous motor, operating at full load and 0.8 leading power factor, is added instead of the capacitor in part (a), calculate the resulting power factor.
Calculate the parameters of the equivalent circuit shown in Figure 13.2.5(c).
Considering the house, the surroundings, and the water tank to be heat reservoirs, what is the power that must be supplied to run the air conditioner per kW of heat pumped out of the house?
A four-pole, dc series motor has a lap-connected, two-layer armature winding with a total of 400 conductors. Calculate the gross torque developed for a flux per pole of 0.02 Wb and an armature current of 50 A. (Note: The number of parallel paths i..
Find the rated and maximum torques.
The star point on the primary side of the transformer bank is grounded. The load consists of a heating load of 2 kW per phase and a three-phase induction-motor load of 20 kVA with a lagging power factor of 0.8, supplied at 230 V line-to-line.
The tongs shown are designed for lifting blocks of ice. If the weight of the ice block is W, find the horizontal force between the tongs and the ice block at C and D.