Four Resistors are connected in parallel. what is the equivalent resistance if their individual resistances are :
r1 =100 Ohms ±5% tolerance
r2 =470 Ohms ±5% tolerance
r3 =330 Ohms ±10% tolerance
r4 =1000 Ohms ±5% tolerance
A 4800/480 volt, single phase transformer is rated at 75KVA. test results performed for rated power showed the following. short circuit test V=80v, P= 2470W, I= Rated current open circuit test V= 480v, I=4Amp, P=616W
Explain and discuss the problems presented by electronic discovery in civil actions and how the law has responded.
Three cells whose open-circuit voltages are each V are connected in series. What is the open circuit voltage of the series connection If the same three cells were connected in parallel
Sketch the DFT(discrete fourier transform)for a square wave with frequency 1Hz and 10 Hz given N=64 and SR(sample rate)=128. Make sure to label your axes.
Draw a labeled sketch of x(t) over a few periods: be careful, make sure you follow the exact definition of x(t)
When the body metabolizes glucose water and carbon dioxide are produced according to the following equation. C6H12O6 + 6 O2 --> 6 CO2 + 6 H2O If 0 g of glucose are metabolized with excess oxygen
A byte containing 01100011 is right shifted (right-most bit first) into an 8-bit shift register with an initial state of 00110110 (01100011=>00110110) What does the shift register contain after three clock pulses
The Hamming distance between two bit strings of the same length is the number of positions in which the strings have different bit values. For example, the Hamming distance between 1110 and 0101 is 3.
Examining frequency to time domain signals, A spectrum analyzer is connected to an unknown signal. The spectrum analyzer displays the power level of signals in dBm vertically and frequency horizontally. The spectrum of the unknown signal creates t..
Efficiency in a power transformer is 98.6 percent when loaded such that its core losses equal the copper losses. Calculate the per unit resistance of this transformer.
A three-phase transmission line having a reactance of 120 ohms per phase is connected to a wye-connected load whose resistance is 160 ohms per phase. If the supply volatge is 70kV line-to-line, calculate a) The line-to-neutral voltage per phase.
When the scope probe is properly calibrated, it can be modeled as a 9[M Ohm] resistor in parallel with a capacitor having a capacitance l/9th that of the oscilloscope input capacitance.