Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
The base width of a npn BJT at a temperature of 300K is 4μm. If the time it takes for an electron to diffuse a distance d is t=d2/Dn, where D is the diffusion coefficient.Calculate α and ß for this BJT. Assume typical electron mobilities and the whole lifetime in the base is 1µs.
A diode is measured to pass 0.31mA at 0.70V forward bias, and 1.12mA at 0.75 V forward bias. What are its n and Is. Assume that kT/q=0.026V. For extra credit, if the diode passes 4mA at 0.9V forward bias, what is its forward parasitic resistance
A buffer amplifier with a gain of 1 V/V has an input resistance of 1M and an output resistance of 10 ohm. It is connected between a 1-V, 100-k ohm source and a 100-ohm load. What load voltage results and what are the corresponding voltage, current,..
use any extragates in existing ICs for inverters when possible. Connect thecircuit and check its operation. the truth table for F1 and F2obtained from the circuit should conform with the minterms listed.
A three phase generator is producing power for a balanced load. Each phase provides an rms voltage of 690 V and an rms current of 1000 A. The angle between the voltage and current in each phase is 20 degrees.
Consider the inverse relation given by z=eSTs - that is, how to map the z-plane into the s-plane. a.) Find an expression for s in terms of z from the relation z = STs. b.) Consider the mapping of the unit circle (I.E. z = 1ejw, - pi
120V, 60 Hz source is connected to a distribution line whose resistance, and inductive reactance is 0.001Ohm, j0.002 Ohm, respectively. Single phase, 100HP, 120V, 0.85 pf. motor; and 100Kw, 120V heater are connected in parallel.
Three of the above single phase transformers are connected as a 3-phase transformer bank. The high voltage side of the transformer bank is connected in Y and the power is supplied to the transformer bank through a transmission line
The contects of a six-bit register are initially 100101. The register is shifted four times to the right, with the serial input being 1101. What are the contents of the register after each shift
Design a combinational circuit that takes two 3-bit binary numbers a2a1a0 and b2b1b0 and generates Modulo-8 addition. Recall that the MOD operation produces the remainder value in an integer division. (Note: Do not use any CAD tool.
A 480 V permanent magnet ac motor is consuming 10 kW at power factor 0.80 lagging. Its speed is 1800 rpm. The winding resistance is 0.5 ohms per phase. Core losses are 100 W. Mechanical losses are 250 W. Stray losses are 1.5% of the input power
Consider a digital communication system in which the received symbol y is equal to : y = x+I+n, where n is AWGN with variant sigma_n^2, I models interference independent of both x and n and x is the data taking values +A and -A.
A permanent magnet dc motor is delivering zero torque when it runs at 1800 rev/min and has 50 V dc applied to its terminals. The armature resistance is 2.0 ohm. What current will the motor need in order to deliver a torque of 2.0 Nm
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd