A small factory utilizes the standard 120V/Hz voltage. When all the heavy machinery is operational, the total electric current flowing into the factory is 5.7 amperes. The phase angle between the voltage and current waveforms is measured to be 4.0 radians. Find the real power dissipated by the factory.
write a program that would send out through the serial port an array of twenty bytes of data( need a FOR loop) stored in memory locations starting from 30H( must use a ponter) with even parity added as the ninth bit.( skip baud rate).
an Armstrong indirect FM modulator to generate an FM carrier with a carrier frequency of 96 MHz and deviation of f=20 KHz. A narrowband FM generator with Fc=200 KHz and adjustable deviation f in range of 9 to 10 Hz is available.
Calculating a DC Current through the telephone handset, A telephone handset has a resistance of 600 ohm. It is connected to the local telephone exchange at a distance of 5 km by a twisted pair that has a loop resistance of 200 ohm per km
Assume that a receiver has a first amplifier stage with a 5KW input resistance, a gain of 300, an input audio signal of 20 mV, and an operating temperature of 27oC. When the amplifier is operating with a bandwidth first of 10 MHz,
The reliability performance of each microprocessor is based on the exponential reliability distribution with the following failure rates: A = 23.5 × 10^-3 , B = 12.5 × 10^-4 , C = 12.5 × 10^-4 and D = 23.5 × 10^-3
Three single phase transformers rated 100kVA 13.2kV/2.4kV are connected in wye-delta on a 3-phase, 18kV line. Calculate the maximum load that can be connected to the transformer bank and the outgoing line voltage
A circuits is needed to realize the transfer function \(T_{v}(s)=\pm \frac{(s+125)(s+500)}{(s+250)(s+1000)}\) (a) Design a circuit using two OP AMPs (b) Design a circuit using only one OP AMP.
Let O be a measurement operator for the of dots facing upwards on a 6-sided 'quantum' die-- a die that can be put into superpositions of states and then measured. The set of possible outcomes is {1,2,...6}.
Explain an engineering solution for the BP Oil Spill in the Gulf of Mexico. Discuss the impact of the above engineering solution in an environmental context. Do not discuss the environmental impact of the BP Oil Spill.
a. Convert all the per unit values to a common kVA of 100 and transmission side voltage base of 2500V b. To maintain one per unit voltage at rated load, find the per unit generator voltage needed.
A junction employs Nd = 8x 10^17cm^-3 and Na= 2 x 10^ 17 cm^-3. The device is at 300K. (a) determine the majority and minority carrier concentrations on both sides (b) Calculate the built-in potential at (i)T=250K (ii)300K
A 13,800/480 V three-phase Wye-Delta-connected transformer bank consists of three identical 100-kVA 7967/480-V transformers. It is supplied with power directly from a large constant-voltage bus.