Determine the maximum negative moment in each span

Assignment Help Civil Engineering
Reference no: EM13563851

A three span continuos beam has spans of 27, 30, 27 feet, total unfactored dead loads are 2,600 pounds per linear foot, unfactored live loads are 2,000 pounds per linear foot. For load combination 1.2D + 1.6L, determine the maximum negative moment in each span and maximum negative moment at each support. remember that live loads shall be placed so as to cause the greatest effect. specify the method that you used to determine the moments

Reference no: EM13563851

Questions Cloud

What total volume of this soil is required to obtain : A construction site requires 35,000 yds^3 of soil in a compacted state with a moist unit weight of 126 pcf at a water content of 14%. if the uncompacted soil currently has a unit weight of 96 pcf and water content of 14%
Determine the gravitational force acting between two spheres : Determine the gravitational force acting between two spheres that are touching each other. The mass of each sphere is 400 kg and the radius is 300mm.
Determine the evaporation rate for a reservoir if the wind : Determine the evaporation rate for a reservoir if the wind speed is 40 mph and the surface temperature is 15 degrees Celsius and the overlaying temperature is 25 degrees Celsius. and the relative humidity is 30 percent
Determine the maximum value of the average : The frame shown consists of four wooden members, ABC, DEF, BE, and CF. Knowing that each member has a 2 3 4-in. rectangular cross section and that each pin has a 12 -in. diameter, determine the maximum value of the average normal stress (a) in member..
Determine the maximum negative moment in each span : A three span continuos beam has spans of 27, 30, 27 feet, total unfactored dead loads are 2,600 pounds per linear foot, unfactored live loads are 2,000 pounds per linear foot. For load combination 1.2D + 1.6L
Plot the shear and moment diagrams for the beam : Given simply supported beam with an overhang. The beam is 12 inches wide by 24 inches deep, and the slab is 6 inches deep. use a roof live load of 20 psf, and a concrete density of 150 pdf
How much sand did he place in the drum : A truck driver used sand to soak up a 1 g spill of lindane (C6H6Cl6). He placed the contaminated soil in an open drum which then filled with 150 L of water during a rainstorm. You test the water and find a concentration of 17 M.
What is the generic soil cleanup criteria for direct contact : Based on Michigan law, (a) what is the generic soil cleanup criteria for direct contact with residential soils contaminated with lead? Report your answer in units of "ppm" (
Calculate the water content and degree of saturation : A jet of water of diameter 75mm moving with a velocity of 25m/s strikes a fixed plates in such a way that the angle between the jet and plate is 60? find the force exerted by the jet on the plate. (a) In the direction normal to the plate and (b) In t..

Reviews

Write a Review

 

Civil Engineering Questions & Answers

  Explain how to estimate the capacity of the existing system

The water level of the reservoir is 150 ft above that of the tank. The intake end of the pipeline is square-edged (k=0.5) and the water coes into the tank through a submerged end (k=1). You are told that the pipe is 12 in in diameter

  What are the bearings of the sides cd-de-ea and ab

What are the bearings of the sides CD,DE,EA, and AB if the side CB has a bearing S 20° 44' 36" W, point A is westerly of B and interior angles in each apex are as follows: A = 95° 14' 23"; E=81° 16' 54"

  Calculate the vertical stress at a depth of 4m vertically

Three point loads 10,000, 7500 and 9000 kN act in line 5m apart near the surface of a soil mass. Calculate the vertical stress at a depth of 4m vertically below the centre (7500kN) load.

  Using pestan model for a project

I want to use PESTAN model for a project, can you please tell me any real scenario with available data on which I can formulate a project preferably related to oklahoma.

  Find the required minimum area for the heat transfer

Assume that the wall separating the steam and seawater is 4 mm of steel, with con- ductivity of 15 W/m K, and that a maximum 5oC difference between the two fluids is allowed in the design.

  Design a column base plate

Design a column base plate for a W10 x 33 column supporting a service dead load of 20 kips and a service live load of 50 kips. The column is supported by a 12-inch x 12-inch concrete pier. Use A36 steel and f 'c = 3 ksi. Answer 12 x 12 x 5/8

  Determine what is the manometer reading at b

Given the manometer reading at A is 100 kPa, D = 10 cm, d = 5 cm, VA = 2 m/s, and specific weight of water is 9800 N/m3, what is the manometer reading at B. Note that flow rate (Q) is constant and Q = VA

  Shear tension and bending of the fixed i-beam

To satisfy desige limitation it is necessary to determine the effect of the 2- kN tension in the cable on the shear tension and bending of the fixed I-beam.

  Determine the coordinates of point e of the lot

Calculate the area of a piece of property bounded by a traverse and circular arc with the following coordinates at angle points: A (1275.11, 1356.11), B (1000.27,1365.70),C (1000.00, 1000.00),D (1450.00, 1000.00)

  Bisection method to find the root of equation

Use the bisection method to find the root of the equation f(x) = x 2 - 4sin(x) = 0. For initial bracketing interval [a,b] , take a=1 and b = 3.

  Verify that the hazen williams equation

Verify that the Hazen Williams equation

  Calculate the specific energy when depth of flow

A rectangular channel of 20 f t width and having n = 0.017 carries flow of 800 f t^3/s. Calculate (a) critical depth (b) the minimum speci c energy (c) the speci c energy when depth of flow is 7 f t.