Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
Design a FIR linear phase filter by approximating the ideal frequency reponse
(H^{d}(e^{jwt})=1, for |w|<= pi/8 )
(0, for pi/8 <= |w| <= pi)
using rectangular window with length = 15
a. Find the filter coefficients
b. Find the difference equation
c. Plot the log magnitude and phase response of the filter
1) 70 lbs/hr of steam at 300 psia, 500oF passes through a turbine which expands it to a pressure of 30 psia. If the turbine operates with an efficiency of 70%: a) What is the temperature of the steam leaving the turbine
Research coal deposits in the USA and US coal mine production. Approximately, what was the US annual production of coal from mines in recent years What was the coal production of the Appalachian or Eastern province
1. Calculate the total (composite) load power factor, true power, reactive power and apparent power. 2. Also calculate the full-load current and the amount of capacitive KVAR needed to bring the overall power factor to .95 lagging.
An electric flux of 151 Nm2/C passes through a flat horizontal surface that has an area of 0.715 m2. The flux is due to a uniform electric field. What is the magnitude of the electric field if the field points 10.3° above the horizontal
Write a testbench stimulus for the below 8-bit Shift-Left Register with Positive-Edge Clock, Serial In and Serial Out. Start with all ones after the 8th=bit shifted to the left all zeros.
a.) What isthe minimum sampling frequency to avoid aliasing b.)If the sampling frequency of fs=2500 samples/sec is used how many samples must be taken to give a frequency resolution of 10Hz
Assume we have an N-bus power system and we know the N x N zero-sequence, positive-sequence, and negative sequence matrices for the system. Write a MATLAB program to find the system bus voltages during a (a) 3-phase balanced short circuit fault at..
Considering that the only parameters known are the input line-to-line voltage of 415V rms (f=50Hz), the firing angle (a= degrees) and the overlap angle (b=15degrees), calculate the Power Factor as seen from the input AC
Consider an impedance Z = (1 + j) Ohms. The voltage phasor across it is 1 V. What is the apparent power consumed on this impedance. b-) What is the real power consumed on the previous load.
A hydroelectric dam has a penstock that discharges 10^5 kg/s of water. The head of the dam is 80m. a. compute the volume of the discharged water per second (flow rate). b. compute the power of the water entering the turbine
The trees can be harvested early at reduced yield: the net profit is then $250T per $1,000 initial investment, for T in years. To the nearest whole year, at what T is the rate of return largest
Derive a minimal state table for an FSM that act as four bit parity generator. For every four bits that are observed on the input w during four consecutive clock cycles, the FSM generates the parity bit p = 1
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd