Mass of Air Required for Combustion of FuelA coal fired boiler uses fuel having the following analysis by mass:
Carbon 81%, hydrogen 5%, oxygen 6 %, ash 8%.
A) Determine the minimum mass of air necessary for complete combustion of 1 kg of fuel.
B) If 40% excess air is supplied, determine the percentage composition of the dry exhaust gases by mass.
The pressure of a sample of gas at a constant temperature of 25 degrees C is increased from 1.0 atm to 1.2 atm. If the original volume was 3.8 liters, what will the new volume be?
Mass of Compound Needed to Prepare 1 oz of a 10% Solution Hydroquinone, USP
Name two analytical methods commonly used in Industrial Hygiene. Illustrate your answer with two typical examples What are the four significant physical parameters that you would use to assess the thermal comfort of employees working in a hot and..
What is the required flow rate of cooling water to the exchanger between the wasteheat boiler and the absorber and how much heat must be removed by the two heat exchangers cooling the recycled absorber liquid? Why is there a need to remove this heat?
Describe issues to be considered when developing an evacuation procedure to help ensure the safe evacuation of employees and visitors in the event of a fire Outline the benefits of undertaking regular fire drills in the workplace
CHE 352 – Spring 2014, In this assignment, students will review some of the concepts of measurements discussed, 4 methods of measuring temperature, 4 methods of measuring fluid pressure
Why a substance is being heated at a fast rate the temperature of decomposition
ECH 3023: Mass Balance around two distillation Columns Using Excel, Derive the simultaneous linear mass balance equations for the system using all the information provided.
Design a Heat Exchanger for the Following Duty: Reduced crude oil leaving a distillation unit with a flow rate of 3166.04 kL/d at 268 oC and is to be cooled to 243 oC by exchange with 62.8 kg/s pre-flashed crude oil coming from pre-flash unit at 206 ..
Important information about Chemicals for Indoor Concrete Flooring Explanations on high solids floor finish chemicals used on indoor concrete flooring
(a) Describe the provisions of Occupational Safety and Health Act 2005 with regard to ‘Substances hazardous to health' (b) Describe four types of hazard which arise from the use of chemicals
Eliminate Differences in composition and eliminate differences in temperature, pressure and phase