Calculate the voltage drop across the capacitance

Assignment Help Electrical Engineering
Reference no: EM13281558

it is desired to have a series RLC circuit that take the same current and powre but operate at a power factor of 0.8 leading
a)For what value of capacitance will these condition exist ,assuming that impressed voltage ,frequency,resistance and inductance remain unchanged?
b)Calculate the voltage drop across the capacitance under this condition.

Reference no: EM13281558

Questions Cloud

Find the electric potential energy of group of three charges : Three charges are to be placed as follows: q1: 10.00 µC at (0.00,0.00) q2: -25.00 µC at (4.00,0.00) and q3: -2.00 µC at (0.00,-3.00), Calculate the electric potential energy of the group of three charges
State the purpose of a hot filtration in a recrystallization : What is the purpose of a hot filtration in a recrystallization. When would a hot filtration step not be necessary or useful in a purification by recrystallization? What experimental observation of the hot solution would let you know that it was no..
What percentage increase money supply should central bank : If the objective is to keep the price level the same next year (i.e., no inflation), what percentage increase in the money supply should the central bank plan for?
What is the expected return of the portfolio : Assume you have 20% of your portfolio invested in Stock A, 40% of your portfolio in Stock B, and the remainder in Stock C.
Calculate the voltage drop across the capacitance : a)For what value of capacitance will these condition exist ,assuming that impressed voltage ,frequency,resistance and inductance remain unchanged. b)Calculate the voltage drop across the capacitance under this condition.
How much ice must they add so that the final temperature : A physics student wants to cool a glass of Diet Cola (mostly water), initially at 27°C, by adding ice initially at -18°C. If there is 250g of Diet Cola in the glass, how much ice must they add so that the final temperature will be 0°C?
What discount rate should the firm apply to a new project : What discount rate should the firm apply to a new project's cash flows if the project has the same risk as the firm's typical project?
Explain a gravimetric titration in the mass of titrant : This problem describes a gravimetric titration in which the mass of titrant is measured instead of the volume. A solution of NaOH was standardized by titration of a known quantity of the primary standard potassium hydrogen phthalate (KHP) which ha..
Determine the circuits reactive power and power factor : A series-connected load draws a current i(t)=4cos(100pt + 10°) A when the applied voltage is v(t) = 120cos(100pt-20°) V. Determine a) The circuit‘s apparent power b) The power factor, pf c) The value of the impedance Z

Reviews

Write a Review

Electrical Engineering Questions & Answers

  Determine the sheet resistance and the contact resistance

Measuring the resistances of the resistors with lengths L1 = 10 µm and L2 = 30 µm, the following values are obtained: R1 = 365-ohm and R2 = 1085-ohm, respectively. If the width of the resistors is 5 µm, determine the sheet resistance and the contac..

  At what coordinate on the x axis is the electric field

Two particles are fixed to an x axis: particle 1 of charge q1 = 2.03 x 10-8 C at x = 16.0 cm and particle 2 of charge q2 = -4.62q1 at x = 77.9 cm. At what coordinate on the x axis is the electric field produced by the particles equal to zero

  The magnetic tape recorder uses linear analog

The magnetic tape recorder uses linear analog to digital encoding. Telephone systems use non linear analog to digital conversion. Explain the difference.

  Calculate the percent increase is attenuation

Rayleigh Scattering. Calculate the % increase is attenuation due to Rayleigh scattering exhibited by light having a free-space wavelength 1535 nm as compared to light having a free space wavelength 1550 nm. Provide your answer in units of [%] and ..

  How many total terms and literals are present in equations

Consider two Functions F = E(1,2,3,5,7,9) and G = E(0,5,7,8,9,11,13,15) a) Use K-maps to minimize the function Fb) Use K-maps to minimize the function G c) How many total terms and literals are present in the two equations

  Determine nyquist sampling rate such that no aliasing occurs

The sampled signal x[n] obtained above is processed by the ideal D-to-C converters with the sampling rate (600 Hz). Obtain the representation of the continuous signal. Determine the Nyquist sampling rate such that no aliasing occurs in the sampled..

  Find the number of turns necessary for the secondary winding

A doorbell is connected to a transformer whose primary contains 3000 turns and which is connected to 120 VAC. If the doorbell requirs 0.2 A at 10 V, find the number of turns necessary for the secondary winding and the current that flows in the pri..

  Determine the rate of heat transfer in the cooling section

Air Enters a cooling section at 97Kpa, 35C and 30 percent relative humidity at a rate of 6m^3/min, where it is cooled until the moisture in the air starts condensing. Determine the temperature of the air at the exit and the rate of heat transfer i..

  Calculate the magnitude and phase angle of terminal voltage

Assuming that the secondary is open-circuited and that the primary is connected to a 13.8-kV source, calculate the magnitude and phase angle (with respect to the high-voltage source) of the voltage at the secondary terminals.

  Determine the number of turns of wire in the secondary coil

A 22000 V, 60 Hz generator is connected to the high voltage side of a 22000-2200V, 500 kVA step down transformer. If the resultant core flux is 0.0683 Wb (max), determine: A) the number of turns of wire in the secondary coil.

  What voltage gain is necessary for the output of amplifier

If the signal is connected to the input of an inverting op-amp circuit, what voltage gain is necessary so that the output of the amplifier produces a change of 2 V for every degree change in temperature

  Determine the turns ratio of each transformer and current

Three single-phase transformer are used to form a three-phase transformer bank rated  13.8kV(delta)/120kV(wye). One side is connected to a three-phase load of 12 MVA at 0.8 power factor lagging. Determine the turns ratio of each transformer

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd